Variance Gamma process as degradation model for prognosis and imperfect maintenance of centrifugal pumps

This paper considers the degradation modelling of a non-monotonous health indicator. A Variance Gamma process is proposed for the degradation modelling and its calibration in presence of data is discussed. The remaining useful lifetime estimation based on this model is considered and its sensitivity to parameters estimates is analysed. The model is applied to real data of leakage rate of centrifugal pump. Eventually, an imperfect maintenance policy is proposed and optimized.

Marwa Belhaj Salem, Mitra Fouladirad, Estelle Deloux. Variance Gamma process as degradation model for prognosis and imperfect maintenance of centrifugal pumps. Reliability Engineering and System Safety, 2022, 223, pp.108417. ⟨10.1016/j.ress.2022.108417⟩. ⟨hal-04063946⟩

Journal: Reliability Engineering and System Safety

Date de publication: 01-07-2022

Auteurs:
  • Marwa Belhaj Salem
  • Mitra Fouladirad
  • Estelle Deloux

Digital object identifier (doi): http://dx.doi.org/10.1016/j.ress.2022.108417


x >